MS Aluminium Three-Phase Asynchronous Motor
MS series aluminium-housing three phase asynchronous motors are developed from Y2 series threephase asynchronous motors,since aluminum-alloy material has been introduced into its housing,end shield,terminal box and removable feet,MS series aluminium-housing motors owns a beautiful appearance and a smooth surface. Despite that,dimensions and output power of MS series aluminium-housing motors.
Category:
Three-phase single motor
E-mail:
- DESCRIPTION
- TECHNICAL DATA
- APPLICATIONS
- PRODUCTION&PACKING
-
- Commodity name: MS Aluminium Three-Phase Asynchronous Motor
MS series aluminium-housing three phase asynchronous motors are developed from Y2 series threephase asynchronous motors,since aluminum-alloy material has been introduced into its housing,end shield,terminal box and removable feet,MS series aluminium-housing motors owns a beautiful appearance and a smooth surface. Despite that,dimensions and output power of MS series aluminium-housing motors.
MS series aluminium-housing three phase asynchronous motors are developed from Y2 series threephase asynchronous motors,since aluminum-alloy material has been introduced into its housing,end shield,terminal box and removable feet,MS series aluminium-housing motors owns a beautiful appearance and a smooth surface. Despite that,dimensions and output power of MS series aluminium-housing motors.
MS series motors have lots of futures such as high efficiency and energy saving, large starting torque,excellent performance, low noise and vibration, compact structure, high reliability, easy operation and etc.
Operating conditions of MS series aluminium-housing motors are identical with Y2 series motors, while efficiency class are in line with Chinese National standard GB 18613-2012 class lI,simultaneously,we supply MS series aluminium-housing motors in conformity with IE3 standard for customers.Product Details

High Quality Copper Core
100% copper coil, high quality cold rolled silicon steeldurable, safe to usesheet, high temperature resistance.
High Quality New Rotor
National standard rotor, high-precision rotor with small jitter.stable operation, standard length.


High Quality insert Bearing
High density precision bearing, rust-proof, moisture-proof and wear-resistant bearing, low noise, quality assurance
-
Technical Data
Ambient Temperature:-15°C≤0≤40°C
Altitude: up to 1000m above sea level
Rated Voltage:220/380V.230/400V.380/660V.400/690V
Rated Frequency:50Hz.60Hz
Connection:Starfor 3kW and below.Delta for 4kW and above
Duty Type: Continuous(S1)
Type
Rated power Current
IN(A)
Rotate speed
r/min
Eff n%
P.F
Tn N.m
Tst/Tn
Tmax/Tn
lst/in
10-3kgm2
Noised
B(A)
Weight
Kg
MS
KW
HP
380V
400V 410V
MS-63M1-2
0.18
0.25
0.53
0.50
0.49
2720
65
0.8
0.63
2.2
2.2
5.5
0.00031
58
4.8
MS-63M2-2
0.25
0.35
0.69
0.66
0.63
2720
68
0.81
0.88
2.2
2.2
5.5
0.00060
58
5.1
MS-71M1-2
0.37
0.5
0.99
0.94
091
2740
70
0.81
1.29
2.2
2.2
6.1
0.00075
61
6.0
MS-71M2-2
0.55
0.75
1.40
1.33
1.28
2740
73
0.82
1.92
2.2
2.3
6.1
0.00090
61
6.5
MS-80M1-2
0.75
1.0
1.77
0.68
1.62
0230
77.4
0.83
2.53
2.2
2.3
6.1
0.00120
64
8.7
MS-80M2-2
1.1
1.5
2.50
2.38
2.29
2830
79.6
0.84
3.71
2.2
2.3
7.0
0.00140
64
9.5
MS-90S-2
1.5
2.0
3.34
3.17
3.06
2840
81.3
0.84
5.04
2.2
2.3
7.0
0.00290
69
11.8
MS-90L-2
2.2
3.0
4.73
4.49
4.33
2840
83.2
0.85
7.40
2.2
2.3
7.0
0.00550
69
13.5
MS-100L-2
3.0
4.0
6.19
5.88
5.67
2870
84.6
0.87
9.98
2.2
2.3
7.5
0.01090
73
21.0
MS-112M-2
4.0
5.5
8.05
7.65
7.37
2890
85.8
0.88
13.22
2.2
2.3
7.5
0.01260
74
28.0
MS-132S1-2
5.5
7.5
10.9
10.4
10.0
2900
87
0.88
18.11
2.2
2.3
7.5
0.03770
77
39.0
MS-132S2-2
7.5
10
14.7
14.0
13.5
2900
88.1
0.88
24.70
2.2
2.3
7.5
0.04990
77
44.5
MS-132M-2
9
12
17.6
16.6
6.0
2930
88.1
0.88
29.6
2.2
2.3
7.5
0.0510
77
46.5
MS-160M1-2
11
15
21
20.0
19.2
2930
89.4
0.89
35.85
2.2
2.3
7.5
0.05500
83
69.2
MS-160M2-2
15
20
28.4
27.0
26.0
2930
90.3
0.89
48.89
2.2
2.3
7.5
0.07500
83
78.0
MS-160L-2
18.5
25
34
32.7
31.5
1310
100.9
0.90
60.30
2.2
2.3
7.5
0.12400
83
88.5
MS-63M1-4
0.12
0.18
0.44
0.42
0.40
1310
57.0
0.72
0.87
2.1
2.3
4.4
0.00050
48
4.8
MS-63M2-4
0.18
0.25
0.62
0.59
0.57
1330
60.0
0.73
1.31
2.1
2.2
4.4
0.00060
48
5.1
MS-71M1-4
0.25
0.35
0.79
0.75
0.72
1330
65.0
0.74
1.80
2.1
2.2
5.2
0.00080
53
6.0
MS-71M2-4
0.37
0.5
1.12
aA
1.03
1390
67.0
0.75
2.66
2.1
2.2
5.5
0.00130
53
6.3
MS-80M1-4
0.55
0.75
1.57
49
0.44
1390
71.0
0.75
3.78
2.4
2.2
5.2
0.00180
58
9.4
MS-80M2-4
0.75
1
88
1.79
1.72
1A00
73.0
0.76
5.15
2.3
2.3
6.0
0.00210
58
10.8
MS-90S-4
1.1
1.5
2.67
2.54
2.44
1400
75.0
0.77
7.5
2.3
2.3
6.0
0.00230
59
12.0
MS-90L-4
1.5
2
3.48
3.31
3.19
1430
78.0
079
10.23
2.3
2.3
6.0
0.00270
59
13.8
MS-100L1-4
2.2
3
4.9
4.65
4.49
1430
80.0
0.81
14.69
2.3
2.3
7.0
0.00540
61
21
MAC-100L2-4
3
4
6.5
6.18
5.95
140
82.0
0.82
20.03
2.3
2.3
7.0
0.00670
61
23.5
MS-112M-4
4
5.5
8.56
8.13
7.84
1440
84.0
0.82
26.53
2.3
2.3
7.0
0.00950
62
29.5
MS-132S-4
5.5
7.5
11.5
10.9
0.5
440
85.0
0.83
36.48
2.3
2.3
7.0
0.02140
69
41.0
MS-132M-4
7.5
10
15.3
14.5
A
1440
87.0
0.84
49.74
2.3
2.3
7.0
0.02960
69
47.5
MS-132M1-4
9
12
18.3
17.4
16.8
1460
87.0
0.84
59.69
2.3
2.3
7.0
0.03806
69
48.5
MS-160M1-4
11
15
22.2
21.1
20.3
1460
88.0
0.84
71.95
2.3
2.3
7.0
0.07470
72
72.5
MS-160L-4
15
20
29.6
28.1
27.1
1460
89.0
0.85
98.12
2.2
2.3
7.5
0.09180
72
85.6
MS-63M1-6
0.09
0.12
0.52
0.49
0.48
840
44.0
0.60
1.02
2.2
2.3
3.5
0.00025
48
4.8
MS-63M2-6
0.12
0.18
0.63
0.60
0.58
840
48.0
0.60
1.36
1.8
1.9
3.5
0.00040
48
5.1
MS-71M1-6
0.18
0.25
0.74
0.70
0.68
850
56.0
0.66
2.02
1.8
1.9
4.0
0.00110
49
6.0
MS-71M2-6
0.25
0.37
0.95
0.90
0.87
850
59.0
0.68
2.81
1.9
2.0
4.0
0.00140
49
6.3
MS-80M1-6
0.37
0.5
1.3
1.24
1.19
890
62
0.70
3.97
1.9
2.0
4.7
0.00160
51
8.9
MS-80M2-6
0.55
0.75
1.79
1.70
1.64
890
65.0
0.72
5.90
1.9
2.0
4.7
0.00190
51
10.4
MS-90S-6
0.75
1
2.09
1.99
1.91
910
69.0
0.72
7.87
1.9
2.1
5.5
0.00290
54
12.1
MS-90L-6
1.1
1.5
2.93
2.78
2.68
910
72.0
0.73
11.54
2.0
2.1
5.5
0.00350
54
13.7
MS-100L-6
1.5
2
3.81
3.62
3.49
940
76.0
0.75
15.24
2.0
2.1
5.5
0.00690
58
23.0
MS-112M-6
2.2
3
5.38
5.11
4.93
940
79.0
0.76
22.35
2.0
2.1
6.5
0.01400
62
28.2
MS-132S-6
3
4
7.2
6.84
6.59
960
81.0
0.76
29.84
2.1
2.1
6.5
0.02860
66
40.3
MS-132M1-6
4
5.5
9.45
8.98
8.65
960
82.0
0.76
39.79
2.1
2.1
6.5
0.03570
66
43.0
MS-132M2-6
5.5
7.5
2.6
12.0
11.50
960
84.0
0.77
54.71
2.1
2.1
6.5
0.04490
66
472
MS-160M-6
7.5
10
17
16.2
5.60
970
87.0
0.77
73.84
2.0
2.1
6.5
0.08100
70
70.6
MS-160L-6
11
15
24.2
23.0
22.20
970
89.0
0.78
108.30
2.0
2.1
6.5
0.11600
70
850
-
Operating Conditions
The electric pump can operate continuously and normally under the following conditions.
● The medium temperature should not exceed+40℃.
● The pH value of the medium is between 4 and 10.
● The density of the medium shall not exceed 1200kg/m.
● The power frequency is 50Hz, and the voltage fluctuation range is 0.9-1.1 times the rated value.
● The diving source does not exceed 5m.Application
Widely used in agricultural irrigation and drainage, septic tankdrainage, domestic sewage, water channel cleaning andengineering drainage pollution. It can also be used to pumpmuddy water, waste water, domestic sewage, feces and urine, aswell as sewage and waste water containing solid particles such asshort fiber paper scraps and sediments

-
Production Process








Product Packaging








Exhibitions and Customers








Keywords:
Other Products
Product Cosulting