YCL Series Single-Phase Asynchronous Motor

YCL series single-phase industrial capacitor start motors are made according to IEC standards.These are superior delivering excellent torque with good appearance. Easy maintance,reliable operation.They perform well in voltage fluctuating regions and are commonly used in the pump,compressor,agriculture,farming,building service and manufacturing industry.

Category:

Single-phase motors


  • DESCRIPTION
  • TECHNICAL DATA
  • APPLICATIONS
  • PRODUCTION&PACKING
    • Commodity name: YCL Series Single-Phase Asynchronous Motor

    YCL series single-phase industrial capacitor start motors are made according to IEC standards.These are superior delivering excellent torque with good appearance. Easy maintance,reliable operation.They perform well in voltage fluctuating regions and are commonly used in the pump,compressor,agriculture,farming,building service and manufacturing industry.

    YCL series single-phase industrial capacitor start motors are made according to IEC standards.These are superior delivering excellent torque with good appearance. Easy maintance,reliable operation.They perform well in voltage fluctuating regions and are commonly used in the pump,compressor,agriculture,farming,building service and manufacturing industry.

     

    Product Details

    High Quality Copper Core

    100% copper coil, high quality cold rolled silicon steeldurable, safe to usesheet, high temperature resistance.

    High Quality New Rotor

    National standard rotor, high-precision rotor with small jitter.stable operation, standard length.

    High Quality insert Bearing

    High density precision bearing, rust-proof, moisture-proof and wear-resistant bearing, low noise, quality assurance

  • Model

    Power

    KW

    Rotate speed

    r/min

    Current A

    Voltags

    Eff %

    P.F.

    Cos  φ

    LRT/RLT

    BDT/RLT

    LRA/RLA

    Noise

    LodB (A)

    Weight

    ka

    YCL711-2

    0,37

    2800

    2.7

    220

    67

    0.92

    1.8

    1.7

    16

    72

    10

    YCL712-2

    0,55

    2800

    3.9

    220

    70

    0,92

    1.8

    1.7

    21

    72

    11

    YCL711-4

    0.25

    1400

    2.0

    220

    62

    0.92

    1.8

    1.7

    12

    67

    9

    YCL712-4

    0.37

    1400

    2.8

    220

    65

    0.92

    1.8

    1.7

    16

    67

    10

    YCL801-2

    0,75

    2800

    5.1

    220

    72

    0.92

    1.8

    1.7

    29

    75

    14

    YCL802-2

    1.1

    2800

    7.0

    220

    75

    0.95

    1.8

    1.7

    40

    75

    15

    YCL801-4

    0.55

    1400

    4.0

    220

    68

    0.95

    1.8

    1.7

    21

    70

    13

    YCL802-4

    0.75

    1400

    5.2

    220

    71

    0.92

    1.8

    1.7

    29

    78

    14

    YCL90S-2

    1,5

    2800

    9,4

    220

    76

    095

    1.7

    1.7

    55

    78

    22

    YCL90L-2

    2.2

    2800

    13.7

    220

    77

    0,95

    1.7

    1.7

    80

    78

    24

    YCL90S-4

    1.1

    1400

    7.2

    220

    73

    0.95

    1.7

    1.7

    40

    73

    21

    YCL90L-4

    .5

    1400

    9.6

    220

    75

    0.95

    1.7

    1.7

    55

    73

    23

    YCL100L-2

    3

    2800

    18.2

    220

    79

    0.95

    1.7

    1.7

    110

    83

    24

    YCL100L1-4

    2.2

    1400

    13.9

    220

    76

    0.95

    1.7

    1.7

    80

    78

    32

    YCL100L2-4

    3

    1400

    18.6

    220

    77

    0.95

    1.7

    1.7

    110

    78

    33

    YCL112M-2

    4

    2800

    24.5

    220

    80

    0.95

    1.7

    1.7

    130

    78

    46

    YCL112M-4

    4

    1400

    24,8

    220

    79

    0.95

    1.7

    1.7

    130

    78

    44

    YCL132M-2

    5.5

    2800

    32.5

    220

    85

    0.9

    2

    1.8

    6.5

    78

    46

    YCL132M-4

    7.5

    1460

    40

    220

    85.5

    0.9

    2

    1.8

    6.5

    78

    65

     

     

  • Operating Conditions

    The electric pump can operate continuously and normally under the following conditions.

    ● The medium temperature should not exceed+40℃.
    ● The pH value of the medium is between 4 and 10.
    ● The density of the medium shall not exceed 1200kg/m.
    ● The power frequency is 50Hz, and the voltage fluctuation range is 0.9-1.1 times the rated value.
    ● The diving source does not exceed 5m.

     

    Application

    Widely used in agricultural irrigation and drainage, septic tankdrainage, domestic sewage, water channel cleaning andengineering drainage pollution. It can also be used to pumpmuddy water, waste water, domestic sewage, feces and urine, aswell as sewage and waste water containing solid particles such asshort fiber paper scraps and sediments

     

  • Production Process

     

    Julante

    Julante

    Julante

    Julante

    Julante

    Julante

    Julante

    Julante

     

    Product Packaging

     

    Julante

    Julante

    Julante

    Julante

    Julante

    Julante

    Julante

    Julante

     

    Exhibitions and Customers

     

    Julante

    Julante

    Julante

    Julante

    Julante

    Julante

    Julante

    Julante

Keywords:

Other Products

Product Cosulting

Submit a message
视频标题