YL High Efficiency Three-Phase Asynchronous Motor

YL series two-value capacitor single-phase asynchronous motors are run by capacitor.Main feature:small size high capacity,strong starting torgue

Category:

Single-phase motors


  • DESCRIPTION
  • TECHNICAL DATA
  • APPLICATIONS
  • PRODUCTION&PACKING
    • Commodity name: YL High Efficiency Three-Phase Asynchronous Motor

    YL series two-value capacitor single-phase asynchronous motors are run by capacitor.Main feature:small size high capacity,strong starting torgue

    YL series two-value capacitor single-phase asynchronous motors are run by capacitor.Main feature:small size high capacity,strong starting torgue,high power factor and eficiency,.safety and  reliability in running,simple construction and easy maintenance,it possess 6 frame No.and capacity as three-phase asynchronous motors.This series motors is of totally enclosed fan cooled structure,yL series motors is suitable for machines and equipments such as full load start.

     

    Product Details

    High Quality Copper Core

    100% copper coil, high quality cold rolled silicon steeldurable, safe to usesheet, high temperature resistance.

    High Quality New Rotor

    National standard rotor, high-precision rotor with small jitter.stable operation, standard length.

    High Quality insert Bearing

    High density precision bearing, rust-proof, moisture-proof and wear-resistant bearing, low noise, quality assurance

  • Technical Data

    Ambient temperature:- 15 °C<0<40℃
    Altitude: not exceeding 1000m
    Rated voltage:220V/110V
    Rated fre quency:50Hz、60Hz
    Protection class:IP44、IP54
    Insulation class: ClassB、F级
    Duty:Sl(continuous)
    Cooling method:IC0141

     

    Type

    Output

    Voltage

    (V)

    Current

    (A)

    Speed

    (r/min)

    Eff
    (%)

    P.F

    Locked-rotor
    torque

    Locked-rotor
    current

    Locked-rotor
    torque

    YL

    HP

    KW

    Rated torque
    Tst/Tn
    Rated current
    Tst/Tn
    Rated torque
    Tst/Tn

    YL7112

    0.5

    0.37

    220

    2.73

    2800

    67

    0.92

    1.8

    6.0

    1.8

    YL7122

    0.75

    0.55

    220

    3.88

    2800

    70

    0.92

    1.8

    6.0

    1.8

    YL7114

    0.33

    0.25

    220

    1.99

    1400

    62

    0.92

    1.8

    6.0

    1.8

    YL7124

    0.5

    0.37

    220

    2.81

    1400

    65

    0.92

    1.8

    6.0

    1.8

    YL8012

    1

    0.75

    220

    5.15

    2810

    72

    0.92

    1.8

    6.0

    1.8

    YL8022

    1.5

    1.1

    220

    7.02

    2810

    75

    0.95

    1.8

    6.0

    1.8

    YL8014

    0.75

    0.55

    220

    4.0

    1410

    68

    0.92

    1.8

    6.0

    1.8

    YL8024

    1

    0.75

    220

    5.22

    1410

    71

    0.92

    1.8

    6.0

    1.8

    YL90S-2

    2

    1.5

    220

    9.44

    2820

    76

    0.95

    1.8

    6.0

    1.8

    YL90L-2

    3

    2.2

    220

    13.7

    2820

    77

    0.95

    1.8

    6.0

    1.8

    YL90S-4

    1.5

    1.1

    220

    7.21

    1430

    73

    0.95

    1.8

    6.0

    1.8

    YL90L-4

    2

    1.5

    220

    9.57

    1430

    75

    0.95

    1.8

    6.0

    1.8

    YL100L-2

    4

    3

    220

    18.4

    2850

    78

    0.95

    1.8

    6.0

    1.8

    YL100L1-4

    3

    2.2

    220

    13.9

    1440

    76

    0.95

    1.8

    6.0

    1.8

    YL100L2-4

    4

    3

    220

    18.6

    1440

    77

    0.95

    1.8

    6.0

    1.8

    YL112M-2

    5

    3.7

    220

    22.2

    2850

    80

    0.95

    1.8

    6.0

    1.8

    YL112M-4

    3

    2.2

    220

    13.9

    1450

    76

    0.95

    1.8

    6.0

    1.8

    YL112M1-4

    4

    3

    220

    18.6

    1450

    77

    0.95

    1.8

    6.0

    1.8

    YL112M2-4

    5

    3.7

    220

    23

    1450

    78

    0.95

    1.8

    6.0

    1.8

    YL132S1-4

    4

    3

    220

    18.6

    1460

    77

    0.95

    1.8

    6.0

    1.8

    YL132S2-4

    5

    3.7

    220

    23

    1460

    78

    0.95

    1.8

    6.0

    1.8

    YL132M-4

    7.5

    5.5

    220

    32.49

    1460

    81

    0.95

    1.8

    6.0

    1.8

     

     

  • Operating Conditions

    The electric pump can operate continuously and normally under the following conditions.

    ● The medium temperature should not exceed+40℃.
    ● The pH value of the medium is between 4 and 10.
    ● The density of the medium shall not exceed 1200kg/m.
    ● The power frequency is 50Hz, and the voltage fluctuation range is 0.9-1.1 times the rated value.
    ● The diving source does not exceed 5m.

     

    Application

    Widely used in agricultural irrigation and drainage, septic tankdrainage, domestic sewage, water channel cleaning andengineering drainage pollution. It can also be used to pumpmuddy water, waste water, domestic sewage, feces and urine, aswell as sewage and waste water containing solid particles such asshort fiber paper scraps and sediments

     

  • Production Process

     

    Julante

    Julante

    Julante

    Julante

    Julante

    Julante

    Julante

    Julante

     

    Product Packaging

     

    Julante

    Julante

    Julante

    Julante

    Julante

    Julante

    Julante

    Julante

     

    Exhibitions and Customers

     

    Julante

    Julante

    Julante

    Julante

    Julante

    Julante

    Julante

    Julante

Keywords:

Other Products

Product Cosulting

Submit a message
视频标题