Y Series Three-Phase Induction Motor
Y series motors are totally enclosed and fan cooled(TEFC). three-Phase squirrel cage induction motors. They are newly designed in conformity with the relevant requirements of IEC standards. Y series motors have outstanding performance,such as high efficiency, energy-saving, high starting torque, low noise,little vibration, reliable operation and easy maintenance,etc.
Category:
Three-phase single motor
E-mail:
- DESCRIPTION
- TECHNICAL DATA
- APPLICATIONS
- PRODUCTION&PACKING
-
- Commodity name: Y Series Three-Phase Induction Motor
Y series motors are totally enclosed and fan cooled(TEFC). three-Phase squirrel cage induction motors. They are newly designed in conformity with the relevant requirements of IEC standards. Y series motors have outstanding performance,such as high efficiency, energy-saving, high starting torque, low noise,little vibration, reliable operation and easy maintenance,etc.
Y series motors are totally enclosed and fan cooled(TEFC). three-Phase squirrel cage induction motors. They are newly designed in conformity with the relevant requirements of IEC standards. Y series motors have outstanding performance,such as high efficiency, energy-saving, high starting torque, low noise,little vibration, reliable operation and easy maintenance,etc.
Product Details

High Quality Copper Core
100% copper coil, high quality cold rolled silicon steeldurable, safe to usesheet, high temperature resistance.
High Quality New Rotor
National standard rotor, high-precision rotor with small jitter.stable operation, standard length.


High Quality insert Bearing
High density precision bearing, rust-proof, moisture-proof and wear-resistant bearing, low noise, quality assurance
-
Technical Data
Ambient temperature:-15 °C≤0≤40 °C
Altitude: Not exceeding 1000 meters
Rated voltage:380V士5%
Protection type:IP44/IP54
Connection:Y Start-Connection for 3kw and below
Date-Connection for 3kw or more
Cooling type:ICO141
Insulation class:Class B/Class F
Rated frequency:50Hz/60Hz
Type
Power
W
Amps
A
Speed
rpm
n
%
Cos
Ф
Tst/Tn
Lst/ln
Tmin/Tn
Tmax/Tn
Type
Power
W
Amps
A
Speed
rpm
n
%
Cos
Ф
Tst/Tn
Lst/ln
Tmin/Tn
Tmax/Tn
380V 50Hz 2P
Y315S-4
110
201
1480
93,5
0,89
1.8
6.8
1
2.2
Y80M1-2
0.75
1.8
2830
75
0.84
2.2
6.5
1.5
2.3
Y315M-4
132
241
1490
94
0.89
1.8
6.8
1
2.2
Y80M2-2
1.1
2,5
2830
77
0,86
2.2
7
1.5
2.3
Y315L1-4
160
291
1490
94.5
0.89
1.8
6.8
1
2.2
Y90S-2
1.5
3.4
2840
78
0,85
2.2
7
1.5
2.3
Y315L2-4
200
354
1490
94,5
0.89
1.8
6.8
0,9
2.2
Y90L-2
2.2
4.7
2840
80.5
0.86
2.2
7
1.4
2.3
380V 50Hz 6P
Y100L-2
3
6.4
2870
82
0,87
2.2
7
1.4
2.3
Y80M-6
0,55
1.8
910
71.5
0.7
2
5.5
1.5
2.2
Y112M-2
4
8.2
2890
85,5
0,87
2.2
7
1.4
2.3
Y90S-6
0.75
2.3
910
72.5
0.7
2
5.5
1.5
2.2
Y132S1-2
5.5
11
2900
85.5
0,88
2
7
1.2
2.3
Y90L-6
1.1
3.2
910
73,5
0,72
2
5.5
1.3
2.2
Y132S2-2
7.5
15
2900
86.2
0.88
2
7
1.2
2.3
Y100L-6
1.5
4
940
77,5
0.74
2
6
1.3
2.2
Y160M1-2
11
22
2930
87.2
0.88
2
7
1.2
2.3
Y112M-6
2.2
5.6
940
80.5
0.74
2
6
1.3
2.2
Y160M2-2
15
29
2930
88.2
0,88
2
7
1.2
2,3
Y132S-6
3
7.2
960
83
0.76
2
6.5
1.3
2.2
Y160L-2
18.5
36
2930
89
0,89
2
7
1.1
2.2
Y132M1-6
4
9.4
960
84
0,77
2
6.5
1.3
2.2
Y180M-2
22
42
2940
89
0.89
2
7
1.1
2.2
Y132M2-6
5.5
13
960
85.3
0.78
2
6.5
1.3
2.2
Y200L1-2
30
57
2940
90
0.89
2
7
1.1
2.2
Y160M-6
7.5
17
970
86
0.78
2
6.5
1.3
2
Y200L2-2
37
70
2950
90.5
0,89
2
7
1.1
2.2
Y160L-6
11
25
970
87
0.78
2
6.5
1.2
2
Y225M-2
45
84
2970
91.5
0.89
2
7
1
2.2
Y180L-6
15
31
970
89.5
0.81
1.8
6.5
1.2
2
Y280M-2
55
103
2970
91.5
0.89
2
7
1
2.2
Y200L1-6
18.5
38
970
89.8
0,83
1.8
6.5
1.2
2
Y280S-2
75
140
2970
92
0.89
2
7
0.9
2.2
Y200L2-6
22
45
970
90.2
0.83
1.8
6.5
1.2
2
Y280M-2
90
167
2970
92.5
0,89
2
7
0.9
2.2
Y225M-6
30
60
980
90,2
0,85
1.7
6.5
1.2
2
Y315S-2
110
200
2980
92.5
0,89
1.8
6.8
0.9
2.2
Y250M-6
37
72
980
90.8
0.86
1.8
6.5
1.2
2
Y315M-2
132
237
2980
93
0.89
1.8
6.8
0.9
2.2
Y280S-6
45
85
980
92
0,87
1.8
6.5
1.1
2
Y315L1-2
160
286
2980
93.5
0.89
1.8
6.8
0.9
2.2
Y280M-6
55
104
980
92
0.87
1.8
6.5
1.1
2
Y315L2-2
200
356
2980
93.5
0.89
1.8
6.8
0.8
2.2
Y315S-6
75
141
990
92.8
0.87
1.6
6.5
1
2
380V 50Hz 4P
Y315M-6
90
168
990
93.2
0,87
1,6
6.5
1
2
Y80M1-4
0.55
1.5
1390
73
0.76
2.4
6
1.7
2.3
Y315L1-6
110
204
990
93.5
0,87
1.6
6.5
1
2
Y80M2-4
0.75
2
1390
74.5
0.76
2.3
6
1.6
2.3
Y315L2-6
132
245
990
93.8
0.87
1.6
6.5
1
2
Y90S-4
1.1
2,8
1400
78
0.78
2.3
6.5
1.6
2.3
380V 50Hz 8P
Y90L-2
1.5
3.7
40C
79
0,79
2.3
6.5
1.6
2.3
Y132S-8
2.2
5.6
710
80.5
0.71
2
5.5
1.2
2
Y100L1-4
2.2
5
430
81
0,82
2.2
7
1.5
2.3
Y132M-8
3
7.3
710
82
0.72
2
5.5
1.2
2
Y100L2-4
3
6.8
43C
82,5
0,81
2.2
7
1.5
2.3
Y160M1-8
4
9.5
715
84
0,73
2
6
1.2
2
Y112M-4
4
8.8
400
84.5
0,82
2.2
7
1.5
2.3
Y160M2-8
5.5
12.7
715
85.5
0.74
2
6
1.2
2
Y132S-4
5.5
12
400
85,5
0,84
2.2
7
1.4
2.3
Y160L-8
7.5
17
715
86,1
0,75
2
5.5
1.2
2
Y132M-4
7.5
15
400
87
0,85
2.2
7
1.4
2.3
Y180L-8
11
24.4
730
87
0.77
1.7
6
1.1
2
Y160M-4
11
23
1460
88
0.84
2.2
7
1.4
2.3
Y200L-8
15
32.9
730
88
0.76
1.8
6
1.1
2
Y160L-4
15
30
1460
88,5
0,85
2.2
7
1.4
2.3
Y225S-8
18.5
39.7
735
89.5
0.76
1.7
6
1.1
2
Y180M-4
18.5
36
1470
91
0.86
2
7
1.2
2.2
Y225M-8
22
46,4
735
90
0.78
1.8
6
1.1
2
Y180L-4
22
43
1470
91.5
0.86
2
7
1.2
2.2
Y250M-8
30
61,6
735
90.5
0.8
1.8
6
1.1
2
Y200L-4
30
57
470
92.2
0.87
2
7
1.2
2.2
Y280S-8
37
76.1
740
91
0.79
1.8
6
1.1
2
Y225S-4
37
70
48C
91,8
0,87
1.9
7
1.2
2.2
Y280M-8
45
90.8
740
91.7
0.8
1.8
6
1
2
Y225M-4
45
84
480
92.3
0.88
1.9
7
1.1
2.2
Y315S-8
55
111
740
92
0.8
1.6
6.5
1
2
Y250M-4
55
103
48C
92.6
0.88
2
7
1.1
2.2
Y315M-8
75
150
740
92.5
0.81
1,6
6.5
0.9
2
Y280S-4
75
140
1480
92.7
0.88
1.9
7
1
2.2
Y315L1-8
90
179
740
93
0,82
1.6
6.5
0.9
2
Y280M-4
90
164
1480
93.5
0,89
1.9
7
1
2.2
Y315L2-8
110
219
740
93.3
0.82
1.6
6.3
0.9
2
-
Operating Conditions
The electric pump can operate continuously and normally under the following conditions.
● The medium temperature should not exceed+40℃.
● The pH value of the medium is between 4 and 10.
● The density of the medium shall not exceed 1200kg/m.
● The power frequency is 50Hz, and the voltage fluctuation range is 0.9-1.1 times the rated value.
● The diving source does not exceed 5m.Application
Widely used in agricultural irrigation and drainage, septic tankdrainage, domestic sewage, water channel cleaning andengineering drainage pollution. It can also be used to pumpmuddy water, waste water, domestic sewage, feces and urine, aswell as sewage and waste water containing solid particles such asshort fiber paper scraps and sediments

-
Production Process








Product Packaging








Exhibitions and Customers








Keywords:
Other Products
Product Cosulting